BS 5839 Explained: What Commercial Premises Need From a Fire Detection System

A plain English guide to BS 5839 Part 1 for managing agents and site managers: what the standard covers, the system categories, servicing and who is responsible.

If you manage a commercial building, you will hear BS 5839 mentioned whenever the fire alarm is discussed. This guide explains, in plain English, what British Standard 5839 is, what it asks of a fire detection system in commercial premises, and what it means for the people responsible for the building. It is general guidance, not a substitute for your fire risk assessment or advice on your own building.

What is BS 5839?

BS 5839 is the British Standard for fire detection and fire alarm systems in buildings. It is published in several parts. Part 1 is the code of practice for non domestic premises, such as offices, shops, shopping centres, warehouses, schools and hospitals. Part 6 covers domestic premises. This guide is about Part 1.

Part 1 covers the whole life of a system: how it should be designed, installed, commissioned and handed over, and how it should be maintained afterwards. It is a code of practice, which means it is written as recommendations. In practice it is the benchmark that fire risk assessors, insurers and enforcing authorities expect a commercial system to meet.

The system categories: L, P and M

Before anything is designed, BS 5839 asks what the system is for. The answer is the system category.

  • Category M is a manual system: break glass call points and sounders, with no automatic detection. It relies on people noticing a fire and raising the alarm.
  • Category L systems are designed to protect life. L1 covers the whole building. L2 covers the escape routes plus rooms where a fire is more likely or more dangerous. L3 covers the escape routes and the rooms opening onto them. L4 covers the escape routes themselves. L5 is a custom system designed to deal with a specific risk identified in the fire risk assessment.
  • Category P systems are designed to protect property. P1 covers the whole building and P2 covers defined parts of it, so the fire service can be called as early as possible.

A building can need more than one category, for example L2 for life safety with P2 in a high value storage area. The category should come from the fire risk assessment, and it should be written down so everyone knows what the system was designed to do.

Design, installation and commissioning

Within the chosen category, the designer decides where detectors and call points go, which types of detector suit each area, how the building is split into zones and how the alarm is raised. Call points are normally sited on exits and escape routes, so someone leaving the building can raise the alarm on the way out. Sounders, and voice alarm where it is used, must be loud and clear enough to be heard throughout the areas covered.

On a large site, an addressable system shows the exact device that has operated, which helps staff and the fire service respond and makes faults far easier to find. Choosing detectors is a subject in itself: our guide to the kinds of smoke detectors covers optical, heat, multi sensor, beam and aspirating detection.

When the system is finished, it should be commissioned and handed over with documents including the design, installation and commissioning certificates, record drawings, operating instructions and a logbook.

Servicing and testing

A fire alarm that is not maintained cannot be relied on. BS 5839 Part 1 recommends a routine test by the user, typically weekly, operating a different call point each time so that every one is tried over a period, and periodic inspection and servicing by a competent engineer, normally at intervals of no more than six months. Every test, fault, false alarm and service visit should be written in the logbook.

False alarms matter too. Repeated unwanted alarms disrupt the building, cost time and money, and teach people to ignore the sound. The standard gives guidance on limiting them, from choosing the right detector for each room to managing hot work and contractors.

Who is responsible?

In England and Wales, the Regulatory Reform (Fire Safety) Order 2005 places duties on the responsible person for a non domestic building, usually the employer, the owner or the person in control of the premises. Those duties include a suitable fire risk assessment and making sure fire safety measures, including the fire alarm, are maintained in good working order. Scotland and Northern Ireland have their own legislation with similar duties. In multi tenant buildings, managing agents and tenants often share these duties, so it is worth agreeing in writing who looks after what.

How voice alarm and other systems fit in

In large public buildings, a voice alarm often replaces simple sounders, giving clear spoken instructions zone by zone. Voice alarm equipment is covered by the EN 54 series of standards, and our page on PAVA public address and voice alarm systems explains more. The fire detection system can also be linked to access control, so the right doors release, and to CCTV, so your control room can see the affected area.

Getting help with BS 5839

Zada Technology designs, installs and maintains commercial fire detection systems across the L1 to L5 range, integrated with PAVA, access control and CCTV. If you are not sure whether your current system matches your fire risk assessment, or you need a maintenance contract, contact us to arrange a survey.